Border station Turkey-Greece

Application: Border Station for fiscal metering & Flow control

Solution Equipment:
  • Headers 36” 
  • 2 filter separators 68” body  
  • 3 meter runs with 20” Ultrasonic meter Q-sonic 4C and 20” SMRI Turbinemeter each 
  • 3 flow control valves 18” 
  • 30” Elster-Instromet Ultrasonic meter as By-Pass 
  • Elster-Instromet Encal 3000 gaschromatographs
  • 1 x Water dewpoint analyser
  • 1 x Hydrocarbon dewpoint analyser
  • 1 x Total Sulphur analyser
  • Elster-Instromet Supervisory system & Flow computers,  incl. ESD & automatic flow control    


Design Conditions: Design pressure 80 Barg
Maximum flow 1.655.251 NM3/h